Skip to main navigation Skip to main content
  • KSPTM
  • E-Submission

PHD : Parasites, Hosts and Diseases

OPEN ACCESS
ABOUT
BROWSE ARTICLES
FOR CONTRIBUTORS

Page Path

1
results for

"Heung Jin Jeon"

Article category

Keywords

Publication year

Authors

Funded articles

"Heung Jin Jeon"

Original Article
An Evaluation of a New Quantitative Point-of Care Diagnostic to Measure Glucose-6-phosphate Dehydrogenase Activity
Young Yil Bahk, Seong Kyu Ahn, Heung Jin Jeon, Byoung-Kuk Na, Sung-Keun Lee, Ho-Joon Shin
Korean J Parasitol 2022;60(4):281-288.
Published online August 24, 2022
DOI: https://doi.org/10.3347/kjp.2022.60.4.281
Malaria continues to be one of the most crucial infectious burdens in endemic areas worldwide, as well as for travelers visiting malaria transmission regions. It has been reported that 8-aminoquinolines are effective against the Plasmodium species, particularly primaquine, for anti-hypnozoite therapy in P. vivax malaria. However, primaquine causes acute hemolytic anemia in individuals with glucose-6-phosphate dehydrogenase (G6PD) deficiency. Therefore, G6PD deficiency testing should precede hypnozoite elimination with 8-aminoquinoline. Several point-of-care devices have been developed to detect G6PD deficiency. The aim of the present study was to evaluate the performance of a novel, quantitative G6PD diagnostics based on a metagenomic blue fluorescent protein (mBFP). We comparatively evaluated the sensitivity and specificity of the G6PD diagnostic modality with standard methods using 120 human whole blood samples. The G6PD deficiency was spectrophotometrically confirmed. The performance of the G6PD quantitative test kit was compared with that of a licensed control medical device, the G6PD strip. The G6PD quantitative test kit had a sensitivity of 95% (95% confidence interval (CI): 89.3-100%) and a specificity of 100% (95% CI: 94.3-100%). This study shows that the novel diagnostic G6PD quantitative test kit could be a cost-effective and time-efficient, and universally mandated screening tool for G6PD deficiency.

Citations

Citations to this article as recorded by  Crossref logo
  • Performance of quantitative point-of-care tests to measure G6PD activity: An individual participant data meta-analysis
    Arkasha Sadhewa, Ari Winasti Satyagraha, Mohammad Shafiul Alam, Wondimagegn Adissu, Anup Anvikar, Germana Bancone, Praveen K. Bharti, Vinod K. Bhutani, Santasabuj Das, Muzamil Mahdi Abdel Hamid, Mohammad Sharif Hossain, Nitika Nitika, Bernard A. Okech, Ly
    PLOS Neglected Tropical Diseases.2025; 19(3): e0012864.     CrossRef
  • Utilization of Glucose-6-Phosphate Dehydrogenase Test and the Prevalence of Enzyme Deficiency in Korea
    Rihwa Choi, Wonseo Park, Gayoung Chun, Sang Gon Lee, Eun Hee Lee
    Journal of Clinical Medicine.2023; 12(9): 3179.     CrossRef
  • 6,163 View
  • 166 Download
  • 2 Web of Science
  • Crossref